Skip to content
The concept

From AC to DC — and why it matters

Our electricity grid is built on alternating current. But solar, storage and charging are natively direct current. We explain why many local grids run better on direct current — and what that means for you.

A miniature DC microgrid on a workbench: a small solar panel wired to copper busbarsFrom 50 Hz AC to flat DC

What is the difference — and why now?

Electricity flows in two ways. With alternating current (AC) the current reverses direction fifty times per second. That is handy for transforming voltage and transporting it over long distances — our entire public grid is built that way.

With direct current (DC) the energy flows in one direction, at a constant voltage. Solar panels, batteries, heat pumps and charging points all run on direct current internally.

Today we first convert that direct current to alternating current for the grid, and back to direct current for the device at the other end. Every conversion costs energy and makes the grid more complex. In many local grids — a farm, a business park, a neighbourhood — it can be simpler: connect the sources and consumers directly on a shared DC grid.

AC versus DC

Two ways to build the same grid.

The same sources and consumers, two topologies. On the left the existing AC grid, where every DC connection gets its own converter; on the right one AC/DC coupling to the public grid and, behind it, a shared DC bus with DC/DC converters only.

ACA conversion at every node
Conventional AC topologyThe public AC grid feeds a transformer and an AC bus. PV delivers through a DC/AC inverter, while the battery and the charging point each sit behind their own AC/DC converter — so power from PV to the battery crosses the AC/DC boundary twice.GRID ACTRANSFORMERAC BUSDC/ACAC/DCAC/DCPVBATTERYEV CHARGE
PV → battery: 2 AC/DC conversions
DCA single conversion to the grid
Direct-current topology, highlightedOne bidirectional AC/DC coupling connects the public AC grid to a shared DC bus. PV, battery and charging point each sit behind a DC/DC converter, so power from PV to the battery or the car stays DC throughout: no AC/DC conversion, and one controlled connection to the grid instead of one per node.GRID ACAC/DC COUPLINGDC BUSDC/DCDC/DCDC/DCPVBATTERYEV CHARGE
PV → battery: no AC/DC conversion
  • Power flow
  • AC/DC converter
  • DC/AC inverter
  • DC/DC converter
  • Bus / busbar

Both topologies sit behind the same grid connection; the transformer is drawn on the left only, and the grid coupling works in both directions. Existing AC machines connect directly on AC and through their own inverter on DC — the gain is in sources, storage and charging, which are already DC internally.

The core

On DC a single controlled coupling to the grid replaces the conversion at every node — fewer losses, and visibility and control down to every connection point.

Play with the ring: see where the difference between generation and use lands.

Toggle nodes on or off and switch between AC and DC. A DC bus is always in balance: the difference runs through the grid coupling, to or from the public grid. In AC mode you see what that same picture costs — an AC/DC conversion at every node, and a separate meter per connection.

DC ring / worked example
View as

Conversions between AC and DC:AC 3×DC 2×

DC — Grid coupling: balanced, 0.0 kW

6.4 kW comes in from Solar PV. 6.4 kW goes to House, EV charger and Battery storage. That balances exactly: nothing goes to or from the grid.

Tap a node to switch it on or off

Why this matters

DC — On a DC bus every node sits behind its own converter, which already measures and controls itself — so per-node metering and control come with the architecture. Converting between alternating and direct current happens once, at the grid coupling (▣); only a node that is internally AC — the house, for instance — still needs an inverter of its own.

A DC bus is always in balance: the difference between sources and consumers runs through the grid coupling, to or from the public grid. Switch a node off and see where that difference lands.

  • Supplies power
  • Uses power
  • Storage
  • DC flow
  • Conversion between AC and DC

The physics, made visible.

Solar inverters and charging points switch at high speed. On the AC grid they inject high-frequency harmonics in the process — pollution the grid has to absorb. A DC section removes a large part of that complexity.

Oscilloscope — CH1 · AC / CH2 · DCDistorted alternating current: a sine wave with added harmonics, showing grid degradation. Compared with: Steady DC level with minor ripple — an almost flat line a little above the zero line.CH1 · ACCH2 · DC
CH1 · ACVpp 6.0 Vf 50 HzCH2 · DCVpp 0.50 Vf DC5 ms/div · 1 V/div
Fig. 1 — AC with harmonics vs. flat DC
Enkellijnsschema van een DC-sectie: het openbare net voedt via één omvormer een DC-bus die zon, opslag en laadpaal bedient.PUBLIC GRIDAC/DC CONVERTERDC BUS · 700 VSOLARSTORAGEEV CHARGER
Fig. 2 — DC section: sources and consumers on one bus
Under the hood

The physics in detail

In short: every conversion between AC and DC introduces switching noise. The more conversions in a chain, the more harmonic pollution and the more loss.
Example
Connected solar park150kW PVcompatible with grid and neighbours

On a sunny day, a farm with 150 kW of solar panels produces far more than the business itself consumes. On the existing grid that quickly hits the limits of the connection — and the neighbours notice. With a DC grid on the yard we connect the panels, the storage and the charging points directly.

Enkellijnsschema van de boerderij: 150 kW zon en opslag op een gedeelde DC-bus die de buren voedt en via één netkoppeling met het openbare net verbindt.150 KW PVPUBLIC GRIDFARM DC GRIDGRID COUPLINGSTORAGENEIGHBOURS
Fig. 3 — Farm on a shared DC grid

Worked example

The energy flows become measurable, shareable and controllable, and a single controlled grid coupling keeps the farm cooperating neatly with the public grid.

Questions that come up often.

Isn't direct current dangerous?

Direct current is no more dangerous than alternating current, provided the grid is well designed. DC does require different protection: switches and fuses must be able to interrupt a DC arc, and earthing and insulation monitoring are matched to the voltage. This is known, proven technology — we apply the same safety principles you know from the existing grid.

Does this work with my existing installation?

In most cases, yes. Solar panels, batteries and charging points are already direct current internally, so they connect naturally. Existing AC devices keep working via the grid coupling or a local inverter. We usually design a DC section alongside what is already there, so you can switch over step by step.

What does it cost?

That depends on the situation: the number of sources and consumers, the desired storage and the grid connection. The gain lies in fewer conversion losses, less equipment and more use of your own generation. We are happy to work through a concrete case with you and show where the payback lies.

Does my whole grid have to be direct current?

No. The strength lies precisely in local DC sections: a yard, a building, a business park. You connect those to the public AC grid with a single controlled conversion. The grid as a whole stays AC; only where it pays off does a section run on DC.

Is this already proven in practice?

Yes. Direct current is the standard in data centres, shipping, telecom and industry, and the power electronics are mature. We apply that proven technology to local energy grids and share our knowledge openly with the sector.

Let's talk

Curious whether this fits your situation?

Let's talk — no sales pitch, just a conversation about where direct current makes the difference for you.